Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

9QOD

APH(2'')-IVa with a fragment

This is a non-PDB format compatible entry.
Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALBA BEAMLINE XALOC
Synchrotron siteALBA
BeamlineXALOC
Temperature [K]100
Detector technologyPIXEL
Collection date2020-06-19
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.9897
Spacegroup nameP 1 21 1
Unit cell lengths75.820, 65.269, 77.617
Unit cell angles90.00, 91.53, 90.00
Refinement procedure
Resolution49.950 - 2.290
R-factor0.1896
Rwork0.187
R-free0.24030
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.008
RMSD bond angle0.885
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwarePHENIX ((1.20.1_4487: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]49.9502.370
High resolution limit [Å]2.2902.290
Number of reflections341083374
<I/σ(I)>14.55
Completeness [%]99.3
Redundancy3.1
CC(1/2)0.9980.954
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP29112% PEG3350, 50-90 mM Ammonium citrate

249697

PDB entries from 2026-02-25

PDB statisticsPDBj update infoContact PDBjnumon