Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

9O4X

Gamma delta T cell receptor bound to CD1d

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX2
Synchrotron siteAustralian Synchrotron
BeamlineMX2
Temperature [K]100
Detector technologyPIXEL
Collection date2023-07-06
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.97958
Spacegroup nameP 43 21 2
Unit cell lengths178.093, 178.093, 75.428
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution46.650 - 2.860
R-factor0.2177
Rwork0.215
R-free0.25530
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.005
RMSD bond angle0.943
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHENIX
Refinement softwarePHENIX (1.21.2_5419)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]46.6503.020
High resolution limit [Å]2.8602.860
Rpim0.491
Number of reflections285164072
<I/σ(I)>16.42.3
Completeness [%]99.898.7
Redundancy10.410.6
CC(1/2)0.9990.750
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP29316% PEG 3350, 0.05M CBTP pH 5

246333

PDB entries from 2025-12-17

PDB statisticsPDBj update infoContact PDBjnumon