9NPV
[4,8,7-2] Shifted tensegrity triangle with an (arm,center,arm) distribution of (4,8,7) base pairs and 2 nt sticky ends
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 17-ID |
Synchrotron site | APS |
Beamline | 17-ID |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2022-07-24 |
Detector | DECTRIS EIGER X 9M |
Wavelength(s) | 1.00743 |
Spacegroup name | H 3 |
Unit cell lengths | 110.467, 110.467, 66.856 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 31.890 - 3.000 |
R-factor | 0.1889 |
Rwork | 0.187 |
R-free | 0.22040 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.004 |
RMSD bond angle | 0.666 |
Data reduction software | autoPROC |
Data scaling software | STARANISO |
Phasing software | PHASER |
Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 55.234 | 55.234 | 3.380 |
High resolution limit [Å] | 2.998 | 9.334 | 2.998 |
Number of reflections | 3444 | 204 | 202 |
<I/σ(I)> | 11.5 | ||
Completeness [%] | 74.7 | ||
Redundancy | 10.7 | ||
CC(1/2) | 0.999 | 0.999 | 0.871 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 100 mM MOPS, 1.25 M magnesium sulfate |