9NK5
[0,7,12-->14] Shifted tensegrity triangle with an (arm,center,arm) distribution of (0,7,12) base pairs and 2 nt sticky ends containing a semi-junction that becomes left-handed
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 17-ID |
Synchrotron site | APS |
Beamline | 17-ID |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2023-02-26 |
Detector | DECTRIS EIGER X 9M |
Wavelength(s) | 1.000000 |
Spacegroup name | H 3 |
Unit cell lengths | 112.776, 112.776, 68.087 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 39.680 - 4.580 |
R-factor | 0.1966 |
Rwork | 0.195 |
R-free | 0.23310 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.005 |
RMSD bond angle | 0.748 |
Data reduction software | autoPROC |
Data scaling software | STARANISO |
Phasing software | PHASER |
Refinement software | PHENIX (1.21.1_5286) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 39.682 | 39.682 | 5.149 |
High resolution limit [Å] | 4.580 | 9.406 | 4.584 |
Number of reflections | 1459 | 208 | 210 |
<I/σ(I)> | 10.5 | ||
Completeness [%] | 86.2 | ||
Redundancy | 10.3 | ||
CC(1/2) | 0.997 | 0.997 | 0.349 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 100 mM MOPS, 1.25 M magnesium sulfate |