9NCI
[5,7,7,P-2] Shifted tensegrity triangle with an (arm,center,arm) distribution of (5,7,7) base pairs, 2 nt sticky ends, and 5' phosphates
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 17-ID |
| Synchrotron site | APS |
| Beamline | 17-ID |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2023-03-19 |
| Detector | DECTRIS EIGER X 9M |
| Wavelength(s) | 0.991870 |
| Spacegroup name | H 3 |
| Unit cell lengths | 106.158, 106.158, 90.212 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 32.430 - 4.710 |
| R-factor | 0.2446 |
| Rwork | 0.242 |
| R-free | 0.28360 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.005 |
| RMSD bond angle | 0.738 |
| Data reduction software | autoPROC |
| Data scaling software | STARANISO |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 64.390 | 64.390 | 5.483 |
| High resolution limit [Å] | 4.708 | 10.239 | 4.708 |
| Number of reflections | 1368 | 195 | 197 |
| <I/σ(I)> | 8.6 | ||
| Completeness [%] | 83.0 | ||
| Redundancy | 7.9 | ||
| CC(1/2) | 0.999 | 0.999 | 0.499 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293 | 100 mM MOPS, 1.25 M magnesium sulfate |