9NBZ
[5,7,7-2] Shifted tensegrity triangle with an (arm,center,arm) distribution of (5,7,7) base pairs and 2 nt sticky ends
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 17-ID |
Synchrotron site | APS |
Beamline | 17-ID |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2022-10-16 |
Detector | DECTRIS EIGER X 9M |
Wavelength(s) | 1.007430 |
Spacegroup name | H 3 |
Unit cell lengths | 106.336, 106.336, 91.072 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 32.510 - 3.980 |
R-factor | 0.2185 |
Rwork | 0.216 |
R-free | 0.24780 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.005 |
RMSD bond angle | 0.720 |
Data reduction software | autoPROC |
Data scaling software | STARANISO |
Phasing software | PHASER |
Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 64.754 | 64.754 | 4.283 |
High resolution limit [Å] | 3.977 | 10.226 | 3.977 |
Number of reflections | 2570 | 197 | 195 |
<I/σ(I)> | 15.9 | ||
Completeness [%] | 89.2 | ||
Redundancy | 10.8 | ||
CC(1/2) | 0.999 | 0.999 | 0.157 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 100 mM MOPS, 1.25 M magnesium sulfate |