9MXK
BRD4-BD1 in complex with cyclic peptide 4.1C
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
| Synchrotron site | Australian Synchrotron |
| Beamline | MX2 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2018-10-20 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 0.9537 |
| Spacegroup name | P 31 |
| Unit cell lengths | 70.121, 70.121, 90.160 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 19.751 - 1.730 |
| Rwork | 0.176 |
| R-free | 0.21290 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.011 |
| RMSD bond angle | 1.862 |
| Data reduction software | autoPROC |
| Data scaling software | autoPROC |
| Phasing software | MOLREP |
| Refinement software | REFMAC (5.8.0430 (refmacat 0.4.88)) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 19.751 | 19.751 | 1.832 |
| High resolution limit [Å] | 1.730 | 4.874 | 1.730 |
| Rmeas | 0.147 | 0.053 | 1.367 |
| Number of reflections | 45685 | 2284 | 2284 |
| <I/σ(I)> | 7.5 | 19.9 | 1.3 |
| Completeness [%] | 94.6 | 100 | 47.3 |
| Redundancy | 7.4 | 7.5 | 7.2 |
| CC(1/2) | 0.999 | 0.999 | 0.242 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 291 | 0.1 M HEPES pH 7.5, 42% v/v Polyethylene glycol 200 |