Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL02U1 |
| Synchrotron site | SSRF |
| Beamline | BL02U1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2024-10-19 |
| Detector | DECTRIS EIGER2 S 9M |
| Wavelength(s) | 0.987 |
| Spacegroup name | P 32 2 1 |
| Unit cell lengths | 79.761, 79.761, 299.191 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 33.270 - 2.700 |
| R-factor | 0.20668 |
| Rwork | 0.204 |
| R-free | 0.26303 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.015 |
| RMSD bond angle | 2.945 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.8.0430) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.830 |
| High resolution limit [Å] | 2.700 | 2.700 |
| Rmerge | 0.188 | 1.053 |
| Rpim | 0.060 | 0.334 |
| Number of reflections | 31093 | 4065 |
| <I/σ(I)> | 10.528 | 1.811 |
| Completeness [%] | 98.6 | 99.09 |
| Redundancy | 10.6 | 10.8 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 6.5 | 277 | 0.1 M BIS-Tris, 0.2 M Magnesium chloride, 20 % w/v polyethylene glycol (PEG) 3350 |