Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL19U1 |
Synchrotron site | SSRF |
Beamline | BL19U1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2024-11-24 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.97918 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 44.015, 70.482, 120.074 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 60.780 - 2.100 |
R-factor | 0.2135 |
Rwork | 0.210 |
R-free | 0.27700 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond angle | 16.951 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX ((1.21_5207: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 60.780 | 2.210 |
High resolution limit [Å] | 2.100 | 2.100 |
Number of reflections | 22718 | 3264 |
<I/σ(I)> | 8.3 | |
Completeness [%] | 100.0 | |
Redundancy | 13.1 | |
CC(1/2) | 0.997 | 0.465 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 100 mM MES pH 7.5, 25% PEG MME 2000, 200 mM Ammonium sulfate, 20 mM DTT |