9LLO
a designed heterotrimer combining natural and synthetic fragments
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL02U1 |
| Synchrotron site | SSRF |
| Beamline | BL02U1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2024-09-17 |
| Detector | DECTRIS EIGER2 X 9M |
| Wavelength(s) | 0.9793 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 15.161, 54.681, 119.046 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 29.760 - 1.800 |
| R-factor | 0.1812 |
| Rwork | 0.179 |
| R-free | 0.21570 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond angle | 14.155 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHENIX |
| Refinement software | PHENIX ((1.21rc1_5109: ???)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 29.760 | 1.864 |
| High resolution limit [Å] | 1.800 | 1.800 |
| Rmeas | 0.140 | |
| Rpim | 0.047 | |
| Number of reflections | 9946 | 9946 |
| <I/σ(I)> | 32.51 | |
| Completeness [%] | 99.5 | |
| Redundancy | 9.2 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 277 | 0.2 M Ammonium citrate tribasic pH 7.0 20% w/v Polyethylene glycol 3350 |