Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

9LBT

DPPIV-VAMP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRF BEAMLINE BL02U1
Synchrotron siteSSRF
BeamlineBL02U1
Temperature [K]100
Detector technologyPIXEL
Collection date2024-05-07
DetectorDECTRIS EIGER2 S 9M
Wavelength(s)0.9791
Spacegroup nameP 21 21 21
Unit cell lengths117.827, 126.370, 136.867
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution32.410 - 1.990
R-factor0.1691
Rwork0.169
R-free0.19540
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond angle6.862
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHENIX
Refinement softwarePHENIX ((1.20.1_4487: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]32.4102.060
High resolution limit [Å]1.9901.990
Rpim0.0370.037
Number of reflections138319138311
<I/σ(I)>14.93
Completeness [%]98.7
Redundancy11.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2960.25 M Ammonium acetate, 0.1 M Tris pH 8.5, 21% w/v Polyethylene glycol 3350