9JAA
P[28] rotavirus VP8*
Experimental procedure
| Experimental method | SINGLE WAVELENGTH | 
| Source type | SYNCHROTRON | 
| Source details | SSRF BEAMLINE BL10U2 | 
| Synchrotron site | SSRF | 
| Beamline | BL10U2 | 
| Temperature [K] | 100 | 
| Detector technology | PIXEL | 
| Collection date | 2022-09-03 | 
| Detector | DECTRIS EIGER2 S 9M | 
| Wavelength(s) | 0.97918 | 
| Spacegroup name | P 21 21 21 | 
| Unit cell lengths | 36.680, 41.325, 98.419 | 
| Unit cell angles | 90.00, 90.00, 90.00 | 
Refinement procedure
| Resolution | 31.650 - 1.280 | 
| R-factor | 0.1731 | 
| Rwork | 0.172 | 
| R-free | 0.19460 | 
| Structure solution method | MOLECULAR REPLACEMENT | 
| RMSD bond angle | 6.187 | 
| Data reduction software | autoPROC | 
| Data scaling software | XDS | 
| Phasing software | PHENIX | 
| Refinement software | PHENIX ((1.20.1_4487: ???)) | 
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 34.370 | 1.350 | 
| High resolution limit [Å] | 1.280 | 1.280 | 
| Rmerge | 0.065 | |
| Number of reflections | 37676 | 5292 | 
| <I/σ(I)> | 17 | 2.7 | 
| Completeness [%] | 96.7 | |
| Redundancy | 8.7 | |
| CC(1/2) | 0.999 | 0.799 | 
Crystallization Conditions
| crystal ID | method | pH | temperature | details | 
| 1 | VAPOR DIFFUSION, HANGING DROP | 289 | 0.1 mol/L MIB (pH5.0), 30%PEG1500 | 