9IYT
ChCODH2 A559W_V610H mutant in 8hour air exposure condition
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PAL/PLS BEAMLINE 5C (4A) |
| Synchrotron site | PAL/PLS |
| Beamline | 5C (4A) |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2023-12-27 |
| Detector | DECTRIS EIGER X 9M |
| Wavelength(s) | 1.0000 |
| Spacegroup name | C 1 2 1 |
| Unit cell lengths | 111.950, 75.997, 71.351 |
| Unit cell angles | 90.00, 111.65, 90.00 |
Refinement procedure
| Resolution | 33.130 - 2.000 |
| R-factor | 0.1687 |
| Rwork | 0.166 |
| R-free | 0.21040 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1su7 |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.114 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | REFMAC |
| Refinement software | PHENIX ((1.20.1_4487: ???)) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 50.000 | 50.000 | 2.030 |
| High resolution limit [Å] | 1.990 | 5.430 | 2.000 |
| Rmerge | 0.089 | 0.054 | 0.628 |
| Rmeas | 0.097 | 0.058 | 0.682 |
| Rpim | 0.038 | 0.022 | 0.263 |
| Number of reflections | 37835 | 1943 | 1844 |
| <I/σ(I)> | 8.5 | ||
| Completeness [%] | 99.9 | 98.8 | 99.9 |
| Redundancy | 6.5 | 7.2 | 6.5 |
| CC(1/2) | 0.994 | 0.997 | 0.850 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 295 | PEG3350, Magnesium chloride, Hepes/NaOH |