Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | NSRRC BEAMLINE BL15A1 |
Synchrotron site | NSRRC |
Beamline | BL15A1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2018-05-11 |
Detector | RAYONIX MX300-HS |
Wavelength(s) | 1.0 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 65.020, 200.679, 240.140 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 29.690 - 2.060 |
R-factor | 0.2086 |
Rwork | 0.206 |
R-free | 0.25020 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.008 |
RMSD bond angle | 1.010 |
Data reduction software | HKL-2000 (2.3.10) |
Data scaling software | SCALEPACK |
Phasing software | MOLREP (11) |
Refinement software | PHENIX ((1.21.1_5286: ???)) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 30.000 | 30.000 | 2.130 |
High resolution limit [Å] | 2.060 | 4.430 | 2.060 |
Rmerge | 0.057 | 0.022 | 0.625 |
Rmeas | 0.026 | 0.741 | |
Rpim | 0.014 | 0.395 | |
Number of reflections | 96188 | 9632 | 9593 |
<I/σ(I)> | 13.3 | ||
Completeness [%] | 98.9 | 95.1 | 100 |
Redundancy | 3.4 | 3.3 | 3.4 |
CC(1/2) | 0.999 | 0.616 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 291.15 | 0.09 M NPS, Morpheus Buffer System 2 pH 7.5, 42% Morpheus Precipitant Mix 4 |