9IQ7
SacM-homologous of AkaM
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL10U2 |
Synchrotron site | SSRF |
Beamline | BL10U2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2022-11-15 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.97919 |
Spacegroup name | P 43 21 2 |
Unit cell lengths | 52.182, 52.182, 202.928 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 50.730 - 1.770 |
R-factor | 0.204 |
Rwork | 0.203 |
R-free | 0.22320 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.006 |
RMSD bond angle | 0.929 |
Data reduction software | XDS |
Data scaling software | autoPROC |
Phasing software | PHASER |
Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.730 | 1.830 |
High resolution limit [Å] | 1.770 | 1.770 |
Number of reflections | 27227 | 2760 |
<I/σ(I)> | 26.03 | |
Completeness [%] | 95.5 | |
Redundancy | 15.1 | |
CC(1/2) | 0.995 | 0.901 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 291.15 | 2.0 M Ammonium sulfate 0.1 M Sodium HEPES 7.5 2 % v/v PEG 400 |