9ILB
HUMAN INTERLEUKIN-1 BETA
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU |
Temperature [K] | 300 |
Detector technology | IMAGE PLATE |
Collection date | 1996-04-01 |
Detector | RIGAKU |
Spacegroup name | P 43 |
Unit cell lengths | 55.020, 55.020, 77.160 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 15.000 - 2.280 |
Rwork | 0.157 |
R-free | 0.21000 |
Structure solution method | OTHER |
Starting model (for MR) | 2i1b |
RMSD bond length | 0.013 |
RMSD bond angle | 2.130 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | TNT |
Refinement software | TNT |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 55.000 | 2.370 |
High resolution limit [Å] | 2.280 | 2.280 |
Rmerge | 0.056 | 0.280 |
Number of reflections | 10313 | |
Completeness [%] | 100.0 | 86 |
Redundancy | 2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | Vapor diffusion, hanging drop * | 8.5 | pH 8.5 |
Crystallization Reagents in Literatures
ID | crystal ID | solution | reagent name | concentration (unit) | details |
1 | 1 | reservoir | ammonium sulfate | 2.4 (M) | |
2 | 1 | reservoir | dithiothreitol | 1 (mM) | |
3 | 1 | reservoir | HEPES | 100 (mM) |