Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE MASSIF-3 |
| Synchrotron site | ESRF |
| Beamline | MASSIF-3 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2024-09-01 |
| Detector | DECTRIS EIGER X 4M |
| Wavelength(s) | 0.96770 |
| Spacegroup name | C 1 2 1 |
| Unit cell lengths | 78.758, 133.933, 82.320 |
| Unit cell angles | 90.00, 101.36, 90.00 |
Refinement procedure
| Resolution | 19.740 - 1.700 |
| R-factor | 0.1626 |
| Rwork | 0.161 |
| R-free | 0.20290 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.060 |
| Data reduction software | XDS (VERSION Jun 30, 2024 BUILT=20240723) |
| Data scaling software | Aimless (Version 0.8.1) |
| Phasing software | PHASER |
| Refinement software | PHENIX (dev_5373) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 19.744 | 1.727 |
| High resolution limit [Å] | 1.698 | 1.698 |
| Rmerge | 0.111 | 1.079 |
| Rmeas | 0.140 | 1.368 |
| Rpim | 0.084 | 0.828 |
| Number of reflections | 87658 | 4387 |
| <I/σ(I)> | 7.5 | 1.9 |
| Completeness [%] | 95.3 | 95.8 |
| Redundancy | 2.4 | 2.4 |
| CC(1/2) | 0.989 | 0.537 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 293.15 | 0.2M Magnesium chloride hexahydrate 20% w/v PEG 3350 + 25% Glycerol |