9I1O
The MK-RSL - sulfato-terphen[3]arene complex, C121 form
This is a non-PDB format compatible entry.
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SOLEIL BEAMLINE PROXIMA 2 |
| Synchrotron site | SOLEIL |
| Beamline | PROXIMA 2 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2024-10-26 |
| Detector | DECTRIS EIGER X 9M |
| Wavelength(s) | 0.98 |
| Spacegroup name | C 1 2 1 |
| Unit cell lengths | 167.523, 45.994, 70.159 |
| Unit cell angles | 90.00, 108.24, 90.00 |
Refinement procedure
| Resolution | 44.660 - 1.640 |
| R-factor | 0.1578 |
| Rwork | 0.156 |
| R-free | 0.19420 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.009 |
| RMSD bond angle | 0.952 |
| Data reduction software | XDS (1.20.1_4487) |
| Data scaling software | Aimless |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 44.660 | 1.670 |
| High resolution limit [Å] | 1.640 | 1.640 |
| Rmerge | 0.113 | 0.788 |
| Rmeas | 0.122 | 0.869 |
| Rpim | 0.046 | 0.357 |
| Number of reflections | 61998 | 2828 |
| <I/σ(I)> | 11 | 1.8 |
| Completeness [%] | 99.6 | 92 |
| Redundancy | 6.9 | 5.4 |
| CC(1/2) | 0.998 | 0.777 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 5.5 | 293 | 25% PEG 3350, 0.1 M Bis-Tris pH 5.5, 0.2 M NaCl |