Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

9HVB

High-efficiency Kemp eliminases by complete computational design

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU
Temperature [K]100
Detector technologyPIXEL
Collection date2023-04-17
DetectorRIGAKU HyPix-3000
Wavelength(s)1.34
Spacegroup nameP 61
Unit cell lengths98.541, 98.541, 40.483
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution25.227 - 2.000
R-factor0.1938
Rwork0.192
R-free0.24200
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.007
RMSD bond angle0.751
Data reduction softwareCrystalClear
Data scaling softwareSCALEPACK
Phasing softwarePHASER
Refinement softwarePHENIX ((1.15.2_3472: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]25.2302.072
High resolution limit [Å]2.0002.000
Rmerge0.1140.507
Rmeas0.524
Rpim0.0300.129
Number of reflections154051519
<I/σ(I)>19.736.03
Completeness [%]99.9100
Redundancy156.03
CC(1/2)0.9980.942
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP3.52920.15 M lithium sulfate monohydrate, 0.1 M citric acid (pH 3.5), and 18% polyethylene glycol (PEG) 6000

250835

PDB entries from 2026-03-18