9HTG
Beta-cardiac myosin E497D mutant motor domain in the pre-powerstroke state, MgADP.VO4 form
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SOLEIL BEAMLINE PROXIMA 2 |
| Synchrotron site | SOLEIL |
| Beamline | PROXIMA 2 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2024-03-23 |
| Detector | DECTRIS EIGER X 9M |
| Wavelength(s) | 0.98012 |
| Spacegroup name | P 43 2 2 |
| Unit cell lengths | 93.427, 93.427, 220.258 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 35.620 - 2.596 |
| R-factor | 0.2033 |
| Rwork | 0.201 |
| R-free | 0.24850 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.007 |
| RMSD bond angle | 0.870 |
| Data reduction software | XDS (1.12.15) |
| Data scaling software | autoPROC (1.0.5) |
| Phasing software | MOLREP (1.20.1-4487-000) |
| Refinement software | BUSTER (2.10.4) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 93.427 | 2.918 |
| High resolution limit [Å] | 2.596 | 2.596 |
| Rmerge | 0.255 | 2.412 |
| Rmeas | 0.260 | 2.464 |
| Rpim | 0.050 | |
| Number of reflections | 19417 | 971 |
| <I/σ(I)> | 10.5 | 1.7 |
| Completeness [%] | 62.6 | 10.8 |
| Redundancy | 26.4 | 23.7 |
| CC(1/2) | 0.998 | 0.788 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8 | 298 | 22 % PEG 3350 w:v, 0.3 M lithium sulfate, 0.1M Tris-HCl, 2 mM Mg.ADP.Vanadate |