Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | DIAMOND BEAMLINE I03 |
| Synchrotron site | Diamond |
| Beamline | I03 |
| Temperature [K] | 173 |
| Detector technology | PIXEL |
| Collection date | 2023-12-06 |
| Detector | DECTRIS PILATUS 6M |
| Wavelength(s) | 0.92 |
| Spacegroup name | I 2 3 |
| Unit cell lengths | 144.890, 144.890, 144.890 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 45.860 - 2.601 |
| Rwork | 0.184 |
| R-free | 0.24470 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.007 |
| RMSD bond angle | 1.899 |
| Data reduction software | xia2 |
| Data scaling software | Aimless |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.8.0430 (refmacat 0.4.82)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 45.860 | 2.720 |
| High resolution limit [Å] | 2.600 | 2.600 |
| Rmerge | 0.041 | 6.600 |
| Number of reflections | 15709 | 1903 |
| <I/σ(I)> | 19.2 | |
| Completeness [%] | 100.0 | 100 |
| Redundancy | 40.5 | 42.2 |
| CC(1/2) | 1.000 | 0.350 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7.6 | 293 | 25 mM HEPES pH 8, 150 mM NaCl, 10 % glycerol, 1 mM DTT 85mM Tris pH 7.6, 140 mM acetate, 23.5 % Polyethylene glycol 4,000, 18% glycerol |