Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID30B |
Synchrotron site | ESRF |
Beamline | ID30B |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2024-02-27 |
Detector | DECTRIS EIGER2 X 9M |
Wavelength(s) | 0.96863 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 39.760, 103.648, 41.868 |
Unit cell angles | 90.00, 104.42, 90.00 |
Refinement procedure
Resolution | 40.550 - 1.280 |
R-factor | 0.1988 |
Rwork | 0.198 |
R-free | 0.22080 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.006 |
RMSD bond angle | 0.767 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | PHENIX (1.21.1_5286) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 40.550 | 1.350 |
High resolution limit [Å] | 1.280 | 1.280 |
Number of reflections | 150574 | 22160 |
<I/σ(I)> | 8.75 | |
Completeness [%] | 90.2 | |
Redundancy | 1.56 | |
CC(1/2) | 0.999 | 0.472 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 295 | 25% PEG 3350, 0.2M Ammonium Sulphate, 0.1M Bis-Tris pH 6.5 |