Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | PETRA III, DESY BEAMLINE P11 |
Synchrotron site | PETRA III, DESY |
Beamline | P11 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2022-07-15 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 1.033202 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 59.914, 74.950, 76.129 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 47.080 - 1.360 |
R-factor | 0.1493 |
Rwork | 0.148 |
R-free | 0.16560 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.016 |
RMSD bond angle | 1.448 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 47.080 | 1.440 |
High resolution limit [Å] | 1.360 | 1.360 |
Rmerge | 0.078 | 0.853 |
Rmeas | 0.083 | 0.895 |
Rpim | 0.025 | 0.266 |
Total number of observations | 776332 | 113983 |
Number of reflections | 72913 | 10514 |
<I/σ(I)> | 14.7 | 2.6 |
Completeness [%] | 99.2 | |
Redundancy | 10.6 | 10.8 |
CC(1/2) | 0.999 | 0.863 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7 | 293 | JSCG+ condition F16: 0.1 M HEPES pH 7, 30% Jeff-M-600 |