Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X10SA |
Synchrotron site | SLS |
Beamline | X10SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2022-10-18 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.99998 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 65.920, 68.208, 421.060 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 210.530 - 2.380 |
R-factor | 0.23625 |
Rwork | 0.236 |
R-free | 0.28547 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.003 |
RMSD bond angle | 1.344 |
Data reduction software | autoPROC |
Data scaling software | autoPROC ((Version 1.1.7)) |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0267) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 210.530 | 2.420 |
High resolution limit [Å] | 2.380 | 2.380 |
Number of reflections | 78066 | 3786 |
<I/σ(I)> | 14.5 | |
Completeness [%] | 99.9 | |
Redundancy | 8.2 | |
CC(1/2) | 0.990 | 0.910 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | BICINE: 0.10 M pH:9.00 ; LiSO4: 0.16M ; PEG 2K MME: 24 %w/v |