9GNX
Human SENP5 in complex with SUMO1 (E67D)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ALBA BEAMLINE XALOC |
Synchrotron site | ALBA |
Beamline | XALOC |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2024-07-07 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.9791 |
Spacegroup name | P 65 2 2 |
Unit cell lengths | 90.350, 90.350, 151.880 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 69.560 - 1.900 |
R-factor | 0.2125 |
Rwork | 0.210 |
R-free | 0.25790 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.012 |
RMSD bond angle | 1.480 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX ((1.17.1_3660: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 69.560 | 1.770 |
High resolution limit [Å] | 1.730 | 1.730 |
Number of reflections | 34776 | 330 |
<I/σ(I)> | 11.3 | |
Completeness [%] | 89.8 | |
Redundancy | 12.7 | |
CC(1/2) | 0.999 | 0.192 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 291 | 0.2 M LiSO4, 8% PEG2000, 8% PEG500MME, 0.1 M NaAcetate pH 5.5 |