9GDI
HUMAN PI3KDELTA IN COMPLEX WITH ISOCUMARIN INHIBITOR 10
This is a non-PDB format compatible entry.
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2013-12-04 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.99998 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 90.474, 108.618, 142.402 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 86.360 - 2.810 |
R-factor | 0.24695 |
Rwork | 0.246 |
R-free | 0.29897 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.007 |
RMSD bond angle | 1.035 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | MOLREP |
Refinement software | REFMAC (5.6.0117) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 86.360 | 3.060 |
High resolution limit [Å] | 2.810 | 2.810 |
Rmerge | 0.035 | 0.451 |
Number of reflections | 34545 | 7702 |
<I/σ(I)> | 25.25 | |
Completeness [%] | 99.0 | |
Redundancy | 5.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 16% PEG6000, 0.10 M KCL, 0.10 M MES |