9GC5
Highly optimized CNS penetrant inhibitors of EGFR Exon20 Insertion Mutations
This is a non-PDB format compatible entry.
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I04 |
Synchrotron site | Diamond |
Beamline | I04 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2021-06-28 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.9795 |
Spacegroup name | P 1 |
Unit cell lengths | 35.872, 76.154, 77.967 |
Unit cell angles | 66.88, 83.58, 87.00 |
Refinement procedure
Resolution | 16.380 - 1.909 |
R-factor | 0.2216 |
Rwork | 0.220 |
R-free | 0.26120 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.008 |
RMSD bond angle | 0.960 |
Data reduction software | MOSFLM |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | BUSTER (2.11.8 (26-JUL-2023)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 71.350 | 2.101 |
High resolution limit [Å] | 1.909 | 1.909 |
Number of reflections | 37199 | 1861 |
<I/σ(I)> | 6.6 | |
Completeness [%] | 88.3 | |
Redundancy | 2.8 | |
CC(1/2) | 0.998 | 0.708 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | PEG 8K 12%w/v, LiSO4 0.5M |