Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

9FW8

VDR complex with UG-650

This is a non-PDB format compatible entry.
Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSOLEIL BEAMLINE PROXIMA 2
Synchrotron siteSOLEIL
BeamlinePROXIMA 2
Temperature [K]100
Detector technologyPIXEL
Collection date2023-11-15
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.98
Spacegroup nameP 65 2 2
Unit cell lengths66.010, 66.010, 264.200
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution38.800 - 2.420
R-factor0.2042
Rwork0.198
R-free0.26140
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.007
RMSD bond angle0.837
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHENIX
Refinement softwareBUSTER (1.20.1_4487)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]47.9602.510
High resolution limit [Å]2.4202.420
Number of reflections139141326
<I/σ(I)>31
Completeness [%]99.9
Redundancy2
CC(1/2)1.0000.992
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7290(NH4)2SO4 1.5 M, BisTris 0.1 M pH 7

250059