Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2023-06-24 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 1.00002 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 53.380, 71.949, 71.995 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 42.920 - 1.600 |
R-factor | 0.18787 |
Rwork | 0.186 |
R-free | 0.22259 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.009 |
RMSD bond angle | 1.643 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0415) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 42.920 | 1.630 |
High resolution limit [Å] | 1.600 | 1.600 |
Number of reflections | 37325 | 1799 |
<I/σ(I)> | 21.1 | 2 |
Completeness [%] | 100.0 | |
Redundancy | 13.2 | |
CC(1/2) | 1.000 | 0.842 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293.15 | 25% PEG3350 -- 0.1M HEPES pH 7.5 |