Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

9FPI

Ni,Fe-CODH : Ti(III)-reduced pH 8.0 + CO

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.1
Synchrotron siteBESSY
Beamline14.1
Temperature [K]100
Detector technologyPIXEL
Collection date2023-01-27
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)0.91841
Spacegroup nameC 1 2 1
Unit cell lengths112.200, 74.930, 71.040
Unit cell angles90.00, 111.39, 90.00
Refinement procedure
Resolution35.220 - 1.010
R-factor0.1275
Rwork0.127
R-free0.14220
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.011
RMSD bond angle1.226
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwarePHENIX ((1.21_5207: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]35.2401.050
High resolution limit [Å]1.0101.010
Rmerge0.069
Rmeas0.075
Number of reflections26936028635
<I/σ(I)>12.6
Completeness [%]94.3
Redundancy6.8
CC(1/2)1.0000.407
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.5291.150.1M HEPES pH 7.5, PEG 2000MME 14-18%