9FPH

Ni,Fe-CODH : Ti(III)-reduced pH 8.0 + CO2

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.1
Synchrotron siteBESSY
Beamline14.1
Temperature [K]100
Detector technologyPIXEL
Collection date2023-01-27
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)0.91841
Spacegroup nameC 1 2 1
Unit cell lengths112.320, 75.240, 71.040
Unit cell angles90.00, 111.33, 90.00
Refinement procedure
Resolution33.110 - 1.010
R-factor0.1171
Rwork0.117
R-free0.13600
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.016
RMSD bond angle1.751
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwarePHENIX ((1.21_5207: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]40.8101.050
High resolution limit [Å]1.0101.010
Rmerge0.079
Rmeas0.085
Number of reflections28431628329
<I/σ(I)>11.3
Completeness [%]99.0
Redundancy6.6
CC(1/2)0.9990.346
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.5291.150.1M HEPES pH 7.5, PEG 2000MME 14-18%

243911