Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

9FPF

Ni,Fe-CODH : Ti(III)-reduced pH 8.0

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.1
Synchrotron siteBESSY
Beamline14.1
Temperature [K]100
Detector technologyPIXEL
Collection date2022-10-13
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)0.91841
Spacegroup nameC 1 2 1
Unit cell lengths112.780, 75.240, 71.450
Unit cell angles90.00, 111.50, 90.00
Refinement procedure
Resolution33.240 - 1.270
R-factor0.1471
Rwork0.146
R-free0.16500
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.008
RMSD bond angle1.051
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwarePHENIX ((1.21_5207: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]40.8701.320
High resolution limit [Å]1.2701.270
Rmerge0.100
Rmeas0.108
Number of reflections14458314260
<I/σ(I)>10.90.8
Completeness [%]99.498.5
Redundancy6.7
CC(1/2)0.9990.389
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.5291.150.1M HEPES pH 7.5, PEG 2000MME 14-18%