UP1 in complex with Z90120418

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04-1
Synchrotron siteDiamond
BeamlineI04-1
Temperature [K]100
Detector technologyPIXEL
Collection date2018-06-29
DetectorDECTRIS PILATUS 6M-F
Wavelength(s)0.91587
Spacegroup nameP 1 21 1
Unit cell lengths38.029, 43.882, 55.875
Unit cell angles90.00, 94.19, 90.00
Refinement procedure
Resolution37.930 - 1.400
R-factor0.174
Rwork0.173
R-free0.19000
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.006
RMSD bond angle0.919
Data reduction softwarexia2
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.20.1_4487)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]37.9301.420
High resolution limit [Å]1.4001.400
Rmerge0.0190.103
Rmeas0.0280.146
Rpim0.0190.103
Total number of observations615362026
Number of reflections356011571
<I/σ(I)>16.53.6
Completeness [%]98.1
Redundancy1.71.3
CC(1/2)0.9990.969
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP8.52890.1 M Tris-HCl, pH 8.50, 25% PEG-4000, 8% 2-Methyl-2,4-pentanediol

223166