Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | DIAMOND BEAMLINE I04-1 |
| Synchrotron site | Diamond |
| Beamline | I04-1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2018-06-29 |
| Detector | DECTRIS PILATUS 6M-F |
| Wavelength(s) | 0.91587 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 37.864, 43.968, 56.083 |
| Unit cell angles | 90.00, 94.64, 90.00 |
Refinement procedure
| Resolution | 37.740 - 1.400 |
| R-factor | 0.1683 |
| Rwork | 0.168 |
| R-free | 0.18080 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.007 |
| RMSD bond angle | 0.986 |
| Data reduction software | xia2 |
| Data scaling software | Aimless |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 37.740 | 1.420 |
| High resolution limit [Å] | 1.400 | 1.400 |
| Rmerge | 0.043 | 0.084 |
| Rmeas | 0.060 | 0.118 |
| Rpim | 0.043 | 0.084 |
| Total number of observations | 63383 | 2206 |
| Number of reflections | 35631 | 1558 |
| <I/σ(I)> | 11.9 | 5.8 |
| Completeness [%] | 98.1 | |
| Redundancy | 1.8 | 1.4 |
| CC(1/2) | 0.992 | 0.969 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 8.5 | 289 | 0.1 M Tris-HCl, pH 8.50, 25% PEG-4000, 8% 2-Methyl-2,4-pentanediol |