9F4H

UP1 in complex with Z106579662

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04-1
Synchrotron siteDiamond
BeamlineI04-1
Temperature [K]100
Detector technologyPIXEL
Collection date2018-06-29
DetectorDECTRIS PILATUS 6M-F
Wavelength(s)0.91587
Spacegroup nameP 1 21 1
Unit cell lengths38.062, 43.938, 55.928
Unit cell angles90.00, 94.38, 90.00
Refinement procedure
Resolution37.950 - 1.400
R-factor0.1816
Rwork0.180
R-free0.20460
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.007
RMSD bond angle1.064
Data reduction softwarexia2
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.20.1_4487)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]37.9501.420
High resolution limit [Å]1.4001.400
Rmerge0.0360.366
Rmeas0.0510.517
Rpim0.0360.366
Total number of observations613922144
Number of reflections345761383
<I/σ(I)>10.31.8
Completeness [%]95.2
Redundancy1.81.6
CC(1/2)0.9980.742
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP8.52890.1 M Tris-HCl, pH 8.50, 25% PEG-4000, 8% 2-Methyl-2,4-pentanediol

222926

PDB entries from 2024-07-24

PDB statisticsPDBj update infoContact PDBjnumon