9F2T
Ferric-mycobactin receptor (FemA)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I04 |
Synchrotron site | Diamond |
Beamline | I04 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2023-02-20 |
Detector | DECTRIS EIGER2 XE 16M |
Wavelength(s) | 0.95374 |
Spacegroup name | P 1 |
Unit cell lengths | 83.678, 84.954, 86.702 |
Unit cell angles | 89.97, 61.60, 66.26 |
Refinement procedure
Resolution | 75.550 - 2.200 |
R-factor | 0.2274 |
Rwork | 0.225 |
R-free | 0.27060 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.007 |
RMSD bond angle | 0.919 |
Data reduction software | xia2 |
Data scaling software | DIALS |
Phasing software | PHASER |
Refinement software | PHENIX (1.14_3260) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 75.550 | 2.080 |
High resolution limit [Å] | 2.050 | 2.050 |
Rmerge | 0.201 | 1.330 |
Number of reflections | 115401 | 5668 |
<I/σ(I)> | 7.1 | |
Completeness [%] | 98.2 | |
Redundancy | 3.6 | |
CC(1/2) | 0.987 | 0.325 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 293 | PEG 400, calcium acetate, sodium chloride |