Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

9EWO

Mpro from SARS-CoV-2 with R4A R298A double mutations

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID23-1
Synchrotron siteESRF
BeamlineID23-1
Temperature [K]100
Detector technologyPIXEL
Collection date2023-02-13
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)0.9677
Spacegroup nameC 1 2 1
Unit cell lengths110.326, 53.464, 46.081
Unit cell angles90.00, 102.40, 90.00
Refinement procedure
Resolution53.877 - 3.002
Rwork0.194
R-free0.27540
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.004
RMSD bond angle1.158
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwareREFMAC
Refinement softwareREFMAC (5.8.0405)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]53.8803.220
High resolution limit [Å]3.0003.000
Number of reflections167841401
<I/σ(I)>6.3
Completeness [%]91.5
Redundancy5.4
CC(1/2)0.9920.311
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP29320% PEG 3350, 0.12 mM benzamidine hydrochloride, 200 mM potassium formate

221051

PDB entries from 2024-06-12

PDB statisticsPDBj update infoContact PDBjnumon