9EVY
SARS-CoV-2 Nucleocapsid N-terminal domain (NTD) mutant E136D
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PETRA III, EMBL c/o DESY BEAMLINE P13 (MX1) |
| Synchrotron site | PETRA III, EMBL c/o DESY |
| Beamline | P13 (MX1) |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2023-09-30 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 0.97626 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 58.865, 55.099, 84.591 |
| Unit cell angles | 90.00, 94.82, 90.00 |
Refinement procedure
| Resolution | 84.290 - 1.550 |
| R-factor | 0.21569 |
| Rwork | 0.215 |
| R-free | 0.23619 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Data reduction software | autoPROC (1.1.7) |
| Data scaling software | Aimless (0.7.13) |
| Phasing software | PHASER (2.8.3) |
| Refinement software | REFMAC (5.8.0425) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 84.292 | 84.290 | 1.580 |
| High resolution limit [Å] | 1.550 | 8.490 | 1.550 |
| Rmerge | 0.053 | 0.053 | 0.395 |
| Rmeas | 0.064 | 0.066 | 0.478 |
| Rpim | 0.036 | 0.039 | 0.267 |
| Number of reflections | 76633 | 479 | 3771 |
| <I/σ(I)> | 16 | 26.8 | 3.9 |
| Completeness [%] | 97.9 | 91.3 | 97.5 |
| Redundancy | 5.9 | 4.6 | 5.9 |
| CC(1/2) | 0.997 | 0.993 | 0.924 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 8 | 293 | 100mM BICINE pH 9.3 20% PEG 3350 |