Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

9EJW

MCMV immunoevasin m11 binding murine CD44

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX2
Synchrotron siteAustralian Synchrotron
BeamlineMX2
Temperature [K]77
Detector technologyCCD
Collection date2018-09-18
DetectorADSC QUANTUM 315
Wavelength(s)0.9537
Spacegroup nameP 21 21 21
Unit cell lengths34.839, 105.768, 112.997
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution47.898 - 1.400
R-factor0.1847
Rwork0.184
R-free0.20240
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.007
RMSD bond angle0.980
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Phasing softwarePHASER
Refinement softwarePHENIX (1.10.1_2155)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]47.9261.480
High resolution limit [Å]1.4001.400
Rmerge1.613
Number of reflections8334183341
<I/σ(I)>12.4
Completeness [%]99.9
Redundancy13.5
CC(1/2)0.9990.595
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP8.529330% w/v PEG3000, 0.2 M lithium sulfate, 0.1 M Tris-HCl, pH 8.5

247947

PDB entries from 2026-01-21

PDB statisticsPDBj update infoContact PDBjnumon