9EJV

Co-MAHF-9 A8R Metal Alpha-Helix Framework

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsMAX IV BEAMLINE BioMAX
Synchrotron siteMAX IV
BeamlineBioMAX
Temperature [K]100
Detector technologyPIXEL
Collection date2024-08-30
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.688801
Spacegroup nameP 1
Unit cell lengths9.682, 16.260, 24.696
Unit cell angles99.61, 97.48, 107.03
Refinement procedure
Resolution15.180 - 0.920
R-factor0.1153
Rwork0.113
R-free0.13480
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.007
RMSD bond angle1.606
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwarePHENIX (1.20.1_4487)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]15.1800.953
High resolution limit [Å]0.9200.920
Number of reflections9050928
<I/σ(I)>9.9
Completeness [%]93.4
Redundancy3.5
CC(1/2)0.9980.710
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1SLOW COOLING298water, acetonitrile, cobalt acetate, sodium hydroxide, methanol

238582

PDB entries from 2025-07-09