9E3K
Cryo EM structure of pertussis toxin in complex with neutralizing Fab PERT-199
This is a non-PDB format compatible entry.
EM specimen
| Vitrification | Yes | 
EM Data Collection
| Microscope | TFS KRIOS | 
| Electron Gun | FIELD EMISSION GUN | 
| Accelerating Voltage (kV) | 300 | 
| Cs (mm) | 2.7 | 
| Energy Filter | GIF Bioquantum | 
| Detector | GATAN K3 (6k x 4k) | 
3D Reconstruction
| Method | SINGLE PARTICLE | 
| Resolution (Å) | 3.2 | 
| Software | EPU,Coot,PHENIX | 
| CTF correction | PHASE FLIPPING AND AMPLITUDE CORRECTION | 