Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

9DPY

BMP-10 with BMP-9 Crystal Contacts

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 24-ID-E
Synchrotron siteAPS
Beamline24-ID-E
Temperature [K]100
Detector technologyCCD
Collection date2022-11-28
DetectorADSC QUANTUM 315
Wavelength(s)0.97918
Spacegroup nameC 2 2 21
Unit cell lengths42.752, 123.038, 120.558
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution61.520 - 1.770
R-factor0.2165
Rwork0.214
R-free0.25120
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.008
RMSD bond angle0.962
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.20.1_4487)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]61.5201.870
High resolution limit [Å]1.7701.770
Rmerge0.0782.426
Rmeas0.0882.727
Rpim0.0401.237
Number of reflections310254391
<I/σ(I)>12.21
Completeness [%]98.897.2
Redundancy8.98.9
CC(1/2)0.9980.531
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP6.229325% (v/v) 1,2-propanediol, 100 mM sodium phosphate dibasic/potassium phosphate monobasic pH 6.2, 10% (v/v) glycerol

237735