Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

9DPV

BMP-9 K357R G389S Dimer Without Radiation Damage in Neutral pH

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 22-ID
Synchrotron siteAPS
Beamline22-ID
Temperature [K]100
Detector technologyPIXEL
Collection date2023-02-17
DetectorDECTRIS EIGER X 16M
Wavelength(s)1
Spacegroup nameI 41 2 2
Unit cell lengths71.105, 71.105, 145.553
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution35.550 - 1.990
R-factor0.2259
Rwork0.224
R-free0.26490
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.009
RMSD bond angle1.248
Data reduction softwareiMOSFLM
Data scaling softwareAimless
Phasing softwareMOLREP
Refinement softwarePHENIX (1.20.1_4487)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]41.3702.040
High resolution limit [Å]1.9901.990
Rmerge0.1461.467
Rmeas0.1681.723
Rpim0.0810.877
Number of reflections13055832
<I/σ(I)>6.41.2
Completeness [%]98.886.7
Redundancy75.6
CC(1/2)0.9880.645
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.5289.151M NaCl, 22-26% glycerol, 0.1 M HEPES pH 7.5

237992

PDB entries from 2025-06-25

PDB statisticsPDBj update infoContact PDBjnumon