9DPS

BMP-9 G389S Dimer Without Radiation Damage in Neutral pH

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 22-ID
Synchrotron siteAPS
Beamline22-ID
Temperature [K]100
Detector technologyPIXEL
Collection date2023-02-17
DetectorDECTRIS EIGER X 16M
Wavelength(s)1
Spacegroup nameI 41 2 2
Unit cell lengths70.774, 70.774, 145.525
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution31.820 - 2.060
R-factor0.2179
Rwork0.216
R-free0.24900
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.008
RMSD bond angle1.038
Data reduction softwareiMOSFLM
Data scaling softwareAimless
Phasing softwareMOLREP
Refinement softwarePHENIX (1.20.1_4487)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]63.6502.120
High resolution limit [Å]2.0602.060
Rmerge0.1111.004
Rmeas0.1301.177
Rpim0.0660.596
Number of reflections11744903
<I/σ(I)>7.22.1
Completeness [%]99.599.9
Redundancy5.86
CC(1/2)0.9930.794
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.5289.151M NaCl, 22-26% glycerol, 0.1 M HEPES pH 7.5