Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

9CA5

Rns pocket mutant - H20A

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsNSLS-II BEAMLINE 17-ID-1
Synchrotron siteNSLS-II
Beamline17-ID-1
Temperature [K]100
Detector technologyPIXEL
Collection date2021-01-22
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.979351
Spacegroup nameP 21 21 21
Unit cell lengths47.730, 97.930, 136.690
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution46.100 - 2.900
R-factor0.2694
Rwork0.264
R-free0.31490
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.006
RMSD bond angle0.749
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHENIX
Refinement softwarePHENIX (1.21.1_5286)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]46.1003.000
High resolution limit [Å]2.9002.900
Number of reflections137051448
<I/σ(I)>3.08
Completeness [%]92.3
Redundancy3.6
CC(1/2)0.9860.074
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2981:1 v/v DMSO, 0.1 M succinnic acid, 14% PEG 3350, 0.03 M glycyl-glycyl-gylcine

237992

PDB entries from 2025-06-25