9C80
Co-structure of SARS-CoV-2 (COVID-19 with covalent inhibitor
This is a non-PDB format compatible entry.
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ALS BEAMLINE 5.0.1 |
Synchrotron site | ALS |
Beamline | 5.0.1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2022-09-29 |
Detector | DECTRIS EIGER X 9M |
Wavelength(s) | 1 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 44.780, 53.866, 114.040 |
Unit cell angles | 90.00, 101.30, 90.00 |
Refinement procedure
Resolution | 55.910 - 1.770 |
R-factor | 0.2212 |
Rwork | 0.219 |
R-free | 0.26490 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.009 |
RMSD bond angle | 1.020 |
Data reduction software | autoPROC |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | BUSTER (2.11.8 (23-JAN-2024)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 55.910 | 1.860 |
High resolution limit [Å] | 1.770 | 1.770 |
Rmerge | 0.056 | 1.210 |
Rmeas | 0.067 | 1.517 |
Rpim | 0.037 | 0.898 |
Total number of observations | 135320 | 14043 |
Number of reflections | 43484 | 5838 |
<I/σ(I)> | 9 | 0.7 |
Completeness [%] | 82.5 | |
Redundancy | 3.1 | 2.4 |
CC(1/2) | 0.999 | 0.416 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7 | 291 | 25% Peg 1500, 0.1M MIB pH 7.0 |