9C05

UIC-1 soaked in equimolar benzene, toluene, isopropylbenzene, and ortho-xylene

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsMAX IV BEAMLINE BioMAX
Synchrotron siteMAX IV
BeamlineBioMAX
Temperature [K]100
Detector technologyPIXEL
Collection date2024-05-11
DetectorDECTRIS EIGER X 9M
Wavelength(s)0.688801
Spacegroup nameP 1 21 1
Unit cell lengths13.853, 13.330, 28.670
Unit cell angles90.00, 90.73, 90.00
Refinement procedure
Resolution12.090 - 0.970
R-factor0.0991
Rwork0.097
R-free0.11120
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.010
RMSD bond angle1.983
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwarePHENIX (1.20.1_4487)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]12.0901.005
High resolution limit [Å]0.9700.970
Number of reflections6310627
<I/σ(I)>21.33
Completeness [%]98.3
Redundancy6.5
CC(1/2)0.9990.968
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1SLOW COOLING298acetonitrile, water