9BTM
NRas 1-169 Q61R in Complex with Shoc2 80-582
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SLS BEAMLINE X10SA |
| Synchrotron site | SLS |
| Beamline | X10SA |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2021-05-13 |
| Detector | DECTRIS EIGER2 S 9M |
| Wavelength(s) | 1 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 78.884, 89.339, 119.768 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 59.880 - 2.730 |
| R-factor | 0.2037 |
| Rwork | 0.202 |
| R-free | 0.23820 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.002 |
| RMSD bond angle | 0.497 |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.21.1_5286) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 71.580 | 2.741 |
| High resolution limit [Å] | 2.700 | 2.732 |
| Rmerge | 0.160 | |
| Number of reflections | 23050 | 225 |
| <I/σ(I)> | 13.2 | 0.7 |
| Completeness [%] | 100.0 | 100 |
| Redundancy | 15 | 6.9 |
| CC(1/2) | 0.998 | 0.359 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7 | 295 | 0.1 M Hepes pH 7, 15% PEG 4000 |