Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-E |
Synchrotron site | APS |
Beamline | 24-ID-E |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2020-06-25 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.97918 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 44.528, 87.877, 89.896 |
Unit cell angles | 90.00, 104.31, 90.00 |
Refinement procedure
Resolution | 39.230 - 1.910 |
R-factor | 0.2166 |
Rwork | 0.214 |
R-free | 0.26130 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.005 |
RMSD bond angle | 0.723 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX (1.21_5207) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 50.000 | 50.000 | 2.020 |
High resolution limit [Å] | 1.910 | 4.200 | 1.950 |
Rmerge | 0.114 | 0.059 | 0.646 |
Rmeas | 0.140 | 0.073 | 0.789 |
Rpim | 0.080 | 0.042 | 0.446 |
Number of reflections | 49105 | 4856 | 4926 |
<I/σ(I)> | 8.4 | ||
Completeness [%] | 96.7 | 93.6 | 98.3 |
Redundancy | 3 | 2.9 | 2.9 |
CC(1/2) | 0.985 | 0.990 | 0.464 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 295 | 13-18% PEG3350, 0.2M NaSCN, 0.1 M Bis-Tris Propane, pH = 7.5 |