Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

9B2W

PIV3 HN with Fab 13

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 14-ID-B
Synchrotron siteAPS
Beamline14-ID-B
Temperature [K]100
Detector technologyPIXEL
Collection date2023-02-11
DetectorDECTRIS EIGER X 16M
Wavelength(s)1.0
Spacegroup nameP 1 21 1
Unit cell lengths81.273, 129.353, 89.454
Unit cell angles90.00, 93.57, 90.00
Refinement procedure
Resolution34.760 - 2.510
R-factor0.2214
Rwork0.219
R-free0.26440
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.004
RMSD bond angle0.692
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHENIX
Refinement softwarePHENIX ((1.20.1_4487: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.600
High resolution limit [Å]2.5102.510
Rmeas0.481
Rpim0.897
Number of reflections612125863
<I/σ(I)>17.8
Completeness [%]97.0
Redundancy1.6
CC(1/2)0.9850.897
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP3000.1M Ammonium sulfate, 0.1M MES pH 6.5, 15% (w/v) PEG 4000

247947

PDB entries from 2026-01-21